V-M.O.L.E. 2

HIGH VALUE VERIFICATION

The V-M.O.L.E.™ 2 thermal profiler is the go-to solution for simple verification of PCB profile performance. Four channels capture all measurements necessary for verifying the proper oven settings. Powered by award-winning M.A.P. software, data capture, download, and analysis are streamlined and intuitive. With separate on/off and record buttons to prevent lost profiles, an expansive storage capacity of up to 200 thermal profiles, and one-button profile confirmation, the V-M.O.L.E. 2 makes setting up, validating, and maintaining proper thermal profiles easy and efficient.

Key Features

PROTECT YOUR TIME AND PROFILER

● Indicators identify if critical systems are “GO” before profiling:
» Internal battery voltage is low
» Internal temp is at or above a threshold
» Memory is full
» All channels are OFF


FLEXIBILITY

● 4 thermocouple inputs
● Uses standard, mini thermocouple connectors
● Multiple thermocouple types supported

PROFILE VERIFICATION

● 4 Channels, all you need to run a profile verification


SPEED

● Sampling at up to 100 samples per second
● Higher sampling rates with higher accuracy


BUILT TO LAST

● High-capacity, off-the-shelf LiPo battery
● Automatic shutdown if internal temperature is too high
● ESD-protected inputs

EASE OF USE

● USB-C communications and charging
● Two-button control (on/off and record)


What’s in the Kit


STANDARD THERMAL PROFILER KIT

ECD P/N: E63-0509-00

  • V-M.O.L.E.™ 2 thermal profiler
  • 260L stainless steel Thermal Barrier
  • 260L Yellow Jacket Thermal Barrier Cover
  • Set of four glass 36-gauge thermocouples
  • M.O.L.E.® MAP Software
  • PC USB C Cable (Set-up & Download)
  • Universal Power Pack Charger
  • Quick Reference Guide
  • Carrying Case
  • Calibration Certificate from ECD’s ISO 17025 accredited lab

Specifications


Full Specifications (Click Here)

THERMOCOUPLE SENSORS (4):


  • Standard mini-thermocouples: Type K, T, J, E, N, R, S & B (Type K Special Limits of error)
  • %RH: ECD VaporWATCH® RH Sensor

DATA ACQUISITION:

  • Sampling Interval: 100 samples/second to 10 minutes/sample
  • Data points: 16 million (2.6 million at 6 channels) or 200 data runs (whichever comes first)
  • Accuracy: +/- 1°C (1.8°F)
  • Resolution: 0.0056°C (0.01°F)*
  • Noise Rejection: 50-60 hrz*
  • Measurement range: -200°C to 1,200°C (-328°F to 2,192°F)

*>= 0.05 seconds/sample


POWER:

  • Battery: LiPo (Lithium Polymer ion) – Rechargeable, 1100mAh
  • Charge Protection: optimized for lithium polymer
  • Charge time: Full – < 4 hours
  • Charge runtime: Full – 6 to 8 Hours
  • Battery Life: 300-400 charging cycles or 3 years (Minimum)
  • Charger input current: 60 ma via USB Interface

PHYSICAL:

  • Dimensions (L x W x H):
    • Profiler: 165.1mm (6.5”) x 89mm (3.5”) x 9.41mm (0.37”)
    • Barrier: 253.9mm (10.0”) x 104mm (4.1”) x 26.9mm (1.06”)
    • Yellow Jacket: 264.6mm (10.4”) x 115mm (4.53”) x 32.5 (1.28”)
  • Weight:
    • Profiler: 0.182 kg (6.4 oz)
    • Barrier: 0.861 kg (30.4 oz)
    • Yellow Jacket: 0.07 kg (2.4 oz)
  • Operational range (Profiler): -40°C to +80°C (-40°F to 176°F)
  • Humidity: 0-85% RH (Non Condensing)

COMMUNICATIONS:

  • Interface: USB 2.0 Compliant (charge; upload; download)
  • Cable: USB Type A to USB-C, 1m (3’)

COMPLIANCE:


PATENT:

  • Patent No. 7,653,502

WARRANTY:

  • 2 years parts and labor

Request Form


Please note that official quotes will be issued beginning May 1st with orders shipping mid May.

Contact Us


ECD NORTH AMERICA (US, CANADA)

Worldwide Headquarters
4287-B SE International Way
Milwaukie, Oregon 97222-8825 U.S.A.

LATAM (MEXICO, CENTRAL, SOUTH AMERICA)
EMEA (EUROPE, MIDDLE EAST, AFRICA)
APAC (ASIA-PACIFIC, CHINA, INDIA)